Resources Blog

Model selection

How to Test GPT Image 2 and Nano Banana 2 on the Same Product Photo

Read “100 mL” on the amber bottle. If an edit drops a zero, the listing shows the wrong size, however good the light looks on the glass.

We haven't run GPT Image 2 or Nano Banana 2 (Gemini 3.1 Flash Image) on this bottle. Here's how to compare them on the same photo before trusting either with a listing.

Photograph the bottle and copy the label

Pick a bottle you own or have permission to photograph and edit. Use a square front view with the cap, base and label edges in frame. Leave space around the shoulders. A plain background makes the outline easy to trace. Keep a neutral gray patch beside the bottle at the edge of the frame; it gives you a reference when comparing a color shift. The patch helps you spot a difference between edits. An uncalibrated photo still can't tell you the bottle's exact color.

Read the smallest line on the physical label. Can you read it in the source file at full size, too? If you can't, take a closer picture before starting. Keep the label transcript for the reviewer. Feeding the words to one model would turn a test of preserving print into a test of drawing supplied text.

What to note before testing either model
FieldWhat to enter before the first edit
OriginalSource filename, permission to use it, pixel dimensions and a file fingerprint or read-only copy. Keep a second, marked copy for the cleanup task.
Package detailsExact label lines, including case, numbers and units. Note the cap color, shoulder shape and where the label ends.
Review viewsNote the coordinates of the label crop and gray patch. Set one display width for the listing preview. Keep any review annotations out of the model inputs.
Run settingsDate, exact model ID or version shown, edit mode, requested output size, aspect ratio, quality and any automatic prompt changes. Write “not exposed” for settings you can't see.

Give each submission an ID. Keep a private record of which model produced it, and show reviewers only the ID. Pick one square output size both can return. If the native sizes differ, keep both originals, note the mismatch and compare extra copies at the smaller shared size. Don't claim that the native resolutions matched. If the exact model or image-edit mode can't be identified, stop that pair rather than substitute a newer model under the old name.

Give each model the same three edits

Start each edit in a fresh session. Use the untouched photo for A and C and the same marked copy for both sides of B. Append just one of the three instructions below to this shared prompt. Keep the wording and crop the same for both models.

PROMPT / TEXT
Edit the supplied square photo. Keep the bottle at its original size and position. Preserve the cap, the label and all its print. Keep the gray reference patch in place. Do not add objects or text.

A. Replace the background

PROMPT / TEXT
Change only the background to pale blue. Leave the bottle, its lighting and its contact shadow alone.

Inspect the shoulder against the new blue. If that area is still the old background color, the cutout is incomplete. If blue has spread onto the cap, the edit has crossed the product edge.

B. Clean up next to small print

PROMPT / TEXT
Remove the pencil dot beside the smallest printed line. Leave the paper texture and every printed character in place. Change nothing else.

For this task only, make one copy of the source and add a small pencil-like dot to a blank part of the label next to the line. Save that marked input once and give the identical copy to both models. Keep the unmarked original as the answer key. A result that simply gives you the dot back has preserved the print but hasn't done the job.

C. Move the light

PROMPT / TEXT
Light the bottle softly from the right. Let the shadow fall to the left. Keep the camera, background color and package design as they are.

Here a new shadow is part of the brief. A bright stripe where the cap used to end is a different matter. Compare the outer edge and the label position before deciding whether a highlight has changed the bottle or just its appearance.

For a small first round, budget two attempts per model per task: twelve submissions in all. Alternate which model goes first. Keep the first two attempts, including refusals and blank images. Don't add an extra attempt for the side you expected to do better. A later round with model-specific prompts answers a different question; TakeWeave's guide to comparing models explains how to keep that round separate and count retries.

Read the label before revealing the model

Have one person assign random IDs to the outputs and keep the model names private until the review is over. Give a second person the source, the task instructions and shuffled copies with neutral filenames and no identifying metadata. Hide the label transcript on the first pass: the reviewer should type what they can actually read. Then compare what they wrote with the original label, character by character. Mark a blurred character unreadable instead of guessing it from the product name.

What to record for each image before revealing the model
CheckWhat counts as evidence
Requested editRecord what changed: blue background, dot removed or light from the right. An unchanged input fails the edit.
Print and labelKeep the transcription, wrong or missing characters, added words and unreadable areas. Look for a shifted label edge as well as spelling mistakes.
Bottle and capPlace the output over the source at half opacity on the same canvas. Note the location of any double edge at the cap, shoulder or base. Don't stretch the bottle to make it fit.
Color and useCompare the gray patch and the package side by side on the same screen. Record a visible cast or uncertain color. Check again at the listing size you picked.

Decide what disqualifies a listing before you open the outputs. For this test, accept a photo only if it completes the edit, preserves the readable print and leaves the product shape, cap and label intact. Reject a visible change to the package color that would misidentify the item. If glare makes color impossible to judge, mark it unresolved and hold the photo. If the unit on the label is wrong, reject the shot even if the lighting is the best of the batch.

Make the decision by task

Reveal which model made each image after the reviewer signs off. For each task and model, report usable outputs out of all attempts, with failures and unresolved reviews shown separately. Two attempts tell you about those edits on that bottle; they don't settle which model makes better product photos in general. If neither preserves the label, keep the photographed bottle and edit the background around it.

Which model would I trust with the smallest line of print? This guide doesn't have paired results that settle that. For your bottle, cover the model names and have someone read the units from each image at the size shoppers will see. Check that reading against the real label. If both images get the units wrong, neither is a keeper, even if one has better lighting.